Rec Tec TroubleshootingSo, the fan and auger were working then after the first blown fuse. Second, if you are using an extension cord, to discount it as the issue, try and connect your grill directly to the external GFCI outlet on your property. Grill Start Up/Cool Down Cycle Grill Start Up Cool Down Cycle. Co-founder Ray Carnes talks you through troubleshooting the ignitor rod in your RT-680, in the rare event you encounter an issue. Once the pellets get wet, it turns into the sawdust. Rec Tec claims 550 degrees but I read that it can go up to 600 degrees Fahrenheit. Get ready your neighbors and families are going to be coming over all the time wanting you to use it! Please click below to access the RT-700 wood pellet grill manual. The computer of the Rec-Tec Grill will not turn on. Check the firepot if the pellets are feeding properly. 0:00 / 7:38 RT-680 • Ignitor Rod Repair | REC TEC Grills recteq 63. Co-founder Ray Carnes talks you through troubleshooting the blower fan in your RT-680, in the rare event you encounter an issue. In the event you need to troubleshoot your REC TEC, co-founder Ron Cundy & General Manager Ben Lesshafft are here to talk you through it! RT-680 • Controller Test Mode | REC TEC Grills. If it works you need not take out the auger and you can easily. Page 33: Troubleshooting Back to Table of Contents We pride ourselves on our grills, grilling accessories, and on our commitment to serve you. The major Rec Tec RT 700 problems are it is not igniting, won't turn on, auger not working, temperature issue, and fire goes out. The temperature issue includes the Rec Tec RT 700 overheating or not heating. Extended inactivity may cause the fan to stick. Secondly, an obstructed fire pot with ash is responsible for insufficient airflow. First off, putting low-quality wood pellets in the hopper is the culprit for not producing the heat you need for grilling. Disconnect the igniter or hot rod wire from the red wire bundle. Inspect the stainless steel burn pot to ensure that is clean of debris, ash and that the Ignitor Rod is not obstructed. The major Rec Tec RT 700 problems are it is not igniting, won’t turn on, auger not working, temperature issue, and fire goes out. In the event you need to troubleshoot your REC TEC, co-founder Ron Cundy & General Manager Ben Lesshafft are here to talk you through it! RT-680 • Controller Test Mode | REC TEC Grills. It must've gotten too humid in there because I had the pellets break down and jam the auger. Select Program Files and open the RECTEC (or Drive3) folder. In “Low” mode the grill will get to its lowest temperature (180°F). This is a simpler version of a Rec Tec grill and does not come with the PID controller. Once REC-TEC is installed, you may place a REC-TEC ICON on your desktop. The blower fan uses a brushless motor. All of these troubles cause much suffering for the users. Maintenance and Cleaning A few simple steps will ensure that your REC TEC BULLSEYE will give you many years of service with minimal effort. Others mentioned that it was fairly easy to assemble. However, you also want to check that the GFCI outlet is working correctly. To troubleshoot Rec Tec controller, the step by step procedures are as follows: 1. Remove the stainless steel Grates, Drip Pan, and Flame Deflector. If suddenly or frequently fire goes out in your Rec Tec RT 700 wood pellet grill, you should follow the ways below to solve it: Replace the defective temperature sensor Properly clean the RTD probe Remove the burn pot’s ash or dirt build-up and clean it Supply pellet consistently in enough amount. You will see this error code if your recteq does not reach 180° within 30 minutes. In the rare event you need assistance in troubleshooting the computer in your RT-680, co-founder Ray Carnes is here to help!Check out rectecgrills. Co-founder Ray Carnes talks you through troubleshooting the blower fan in your RT-680, in the rare event you encounter an issue. Live Chat Mon - Fri 9am - 7pm ET Sat 9am - 3pm ET; Email Support@recteq. Then, cut the end off of the old igniter wire. When I was setting up my new Rec Tec Bull I simply logged into my router and disabled the 5Ghz wireless network. If this occurs, manually turn the blower fan blades with a butter knife or screwdriver. Grill Won’t Light But Pellets Feeding. First, inspect your power cable/extension cord for any obvious signs of damage. Fire up your REC TEC and set to 250ºF. Manual Start Up: In case of ignitor failure, you can start your Rec Tec Mini Grill manually: 1. Got my rec tec stampede about a month ago. Remove the stainless steel Grate, Drip Pan, and Flame Deflector. This last fuse blew right after I plugged it in. Rec Tec Auger Jam or Rec Tec Auger Stuck is a common yet serious grill issue every grill owner faces. This also means that you don’t need to control the grill manually so you can get on with your other activities while you grill away. Page 17: Maintenance & Cleaning. @SafetyDan awesome to hear Rec Tec customer service come through again, but I don't believe that's how the PID is supposed to look after you install it. Second, if you are using an extension cord, to discount it as the issue, try and connect. Please consult the chart below to help resolve issues you. Igniter Failure - The heating element has failed to start a fire. However, there could be an issue with the RTD probe. The ER -2 code shows due to the. STEP 2 – Unfolding the Legs The grill should be lying on its back to unfold the legs. First, inspect your power cable/extension cord for any obvious signs of damage. Your Rec Tec Grill is not heating up or fails to maintain the temperature for several reasons. If you are using a previous generation REC TEC brand model without WiFi, it is the other way around, the ER-1 error code means that the grill is overheating. So you've just assembled your brand new recteq Now what? Jody walks you through the initial burn in process to get you ready to grill! These tips & tricks. It also allows you to set and receive notifications for temperature targets for both the grill and the two probes. 5K subscribers Subscribe 50K views 8 years ago Co-owner Ray Carnes shows how to replace the ignitor rod in your RT-680!. Give us a call at (706) 922-0890 Troubleshooting & Maintenance Temp Issues, Error Codes, Controller Modes, Smoke, Power Issues, and more. You might miss cleaning your RTD probe. Rec Tec Auger Jam or Rec Tec Auger Stuck is a common yet serious grill issue every grill owner faces. When sawdust gets hard, they become very hard. I've had my Rec Tec for a year. Locate the four screws holding the blower fan in place and remove them. • Use a grill brush to clean your cooking grate after every cook to provide years of trouble free use from them. All of these indications will let you know about a faulty hot rod or igniter rod. The RT-2500 BFG’s temperature ranges from 180°F-500°F. com/_ylt=AwrEqe6rB2dkO5sIS0NXNyoA;_ylu=Y29sbwNiZjEEcG9zAzIEdnRpZAMEc2VjA3Ny/RV=2/RE=1684502572/RO=10/RU=https%3a%2f%2fbbqblaze. Congratulations on your RT-B380 Bullseye wood pellet grill, we hope you enjoy it and welcome to the recteq family! Get ready your neighbors and families are going to be coming over all the time wanting you to use it! Please click below to access the RT-B380 Bullseye wood pellet grill manual. com%2frec-tec-error-codes-and-troubleshooting%2f/RK=2/RS=AWlHHZvcQpSJU0JnCkonGshBzSg-" referrerpolicy="origin" target="_blank">See full list on bbqblaze. RT-B380 Bullseye Manual. 5K subscribers Subscribe 50K views 8 years ago Co-owner Ray Carnes shows how to replace the ignitor rod in your RT. It comes with a knob to control the temperature and this also works automatically. Troubleshooting & Maintenance – recteq recteq Troubleshooting & Maintenance Troubleshooting & Maintenance Temp Issues, Error Codes, Controller Modes, Smoke, Power Issues, and more. Turn the grill power on again by hitting the power button. REC TEC GRILLS Ultimate Blend premium hardwood pellets contain approximately 8,200 BTUs of heat per pound and have less than 1% ash residue. Receiving an ER-1 code on your Bullseye or Wi-Fi controller means there February 02, 2022 20:59. Air Flow – Proper air flow is one of the single most important factors in achieving high temperatures. Move the cursor to the Desktop. Just split the network if you have the double-signal router and connect the grill with the old one. Putting wet pellets, obstructions in the hopper or defective auger motor are responsible for the auger issues. Troubleshooting & Maintenance - recteq recteq Troubleshooting & Maintenance Troubleshooting & Maintenance Temp Issues, Error Codes, Controller Modes, Smoke, Power Issues, and more. Changed that one out and it ran for about 5-10 minutes. RT-680 • Computer Troubleshoot | REC TEC Grills recteq 62. recteq Troubleshooting & Maintenance Error Codes Error Codes ER-1: Bullseye/Wi-Fi Controller Receiving an ER-1 code on your Bullseye or Wi-Fi controller means there February 02, 2022 13:59 ER-2: Any Grill Receiving an ER-2 means failure to light. Airflow - Blower fan is not supplying airflow to the fire. Solving the Rec Tec WiFi problems is simple. RT-680 • Ignitor Rod Troubleshoot | REC TEC Grills. Now, install the Molex connector to the new igniter wire. If you are using a previous generation REC TEC brand model without WiFi, it is the other way around, the ER-1 error code means that the grill is overheating. Rec Tec’s wifi app allows you to turn the grill on and off, set and adjust the temperature, and see temperature probe readings. it comes highly recommended for searing and grilling because it gets hot. Contact 706-922-0890 for assistance. Rec Tec Grill Won’t. In the event you need to troubleshoot your REC TEC, co-founder Ron Cundy & General Manager Ben Lesshafft are here to talk you through it! RT-680 • Controller Test Mode | REC. recteq support Receiving an ER-2 means failure to light. The temperature sensor of the grill should be clean so that it shows the right readout of temperature. com (706)-922-0890 Mon - Fri 9am - 7pm ET Sat 9am - 3pm ET; Submit a Ticket 24/7. If the auger gets clogged, it fails to feed the wood pellets from the hopper to the fire-pot. Your Rec Tec Grill is not heating up or fails to maintain the temperature for several reasons. Page 8: Assemble Your Rec Tec Mini Grill. Get ready your neighbors and families are going to be coming over all the time wanting you to use it! Please click below to access the RT-340 wood pellet grill manual. If you notice the pellets are feeding and they are 3. Rec Tec Grill Won’t Light Or Turn On 2. You need to check that the temperature sensor is not bent and not touching the wall of the grill. It blew a fuse that’s a 5 amp fuse which is located right behind the power button. The temperature issue includes. If you notice your Rec Tec auger is not turning, you can simply fix this by vacuuming the auger. Overall, I'm very happy with it. In the event you need to troubleshoot your REC TEC, co-founder Ron Cundy & General Manager Ben Lesshafft are here to talk you through it! RT-680 •. My opinions: PROS:-Very high quality for the price-Customer service is indeed superb. Get Help. Cut and pull out all zip ties you see and free your wires. Using the wifi connectivity, you will be able to control your Rec Tec pellet grill right from your phone, computer or tablet. Page 18: Troubleshooting Check for any loose wire connections. The other reason for ER 2 code would be the igniter rod is fail. 9K subscribers Subscribe 5K views 4 years ago In the rare event you need assistance in troubleshooting the computer in your RT-680,. Troubleshooting & Maintenance – recteq recteq Troubleshooting & Maintenance Troubleshooting & Maintenance Temp Issues, Error Codes, Controller Modes, Smoke, Power Issues, and more. Mastertech59 Well-known member. Often, the system used as the interface between the controller and user could malfunction due to being too outdated. The auger cannot push the hard sawdust and so the auger not turns. Co-founder Ray Carnes talks you through troubleshooting the blower fan in your RT-680, in the rare event you encounter an issue. exe (RECTEC with the red icon if common extensions are not shown) and then left click on Copy. In the rare event you need assistance in troubleshooting the computer in your RT-680, co-founder Ray Carnes is here to help!Check out rectecgrills. Go to My Computer and select the proper drive. Second, if you are using an extension cord, to discount it as the issue, try and connect your grill directly to the external GFCI outlet on your property. 1K subscribers Co-founder Ray Carnes talks you through troubleshooting the ignitor rod in your RT-680, in the rare. Tuck the igniter rod wire into the airbox and replace the fire pot in its place & screw down all four screws. RT-700 Manual recteq support Congratulations on your RT-700 wood pellet grill, we hope you enjoy it, and welcome to the recteq family! Get ready your neighbors and families are going to be coming over all the time wanting you to use it! Please click below to access the RT-700 wood pellet grill manual. Inspect the stainless steel burn pot to ensure that is clean of. Once the pellets get contacted with humidity, they swell up and causing the auger to jam up. Raised and lowered the temp trying to make sure it was good to go before I put a brisket on and it then blew 45-60 minutes into testing it out. First, inspect your power cable/extension cord for any obvious signs of damage. RT-680 • Ignitor Rod Troubleshoot | REC TEC Grills. Rec Tec Auger Jam or Rec Tec Auger Stuck is a common yet serious grill issue every grill owner faces. Next, locate the igniter wires. Causes: Auger Jam/Pellet Bridge - The fuel is unable to reach the fire.